Electronic Positive Response (EPR) & WebTMS

Response

EPR Codes as defined by DigAlert

The response EPR codes are maintained by DigAlert in conjunction with USA North 811 for continuity within the state of California.  These codes are used for members to submit responses to DigAlert's +Response EPR servers.  WebTMS users will automatically post +Responses EPRs when they post a response within WebTMS itself.


For Excavators wishing to check responses, instructions will be posted once the system has been configuredplease see → Checking Electronic Positive Responses.  The responses will be displayed with the description not the code.


Tip
titleMore information!

For more information on what the response codes mean and when to use them, please see Electronic Positive Response Best Practices


Warning

The following codes became effective March 1st, 2020.


Response CodeCloses Ticket (WebTMS Only)Description
000N/AReserved for system use only



001

YesClear - No
Conflict
conflict
002YesClear - No
Conflict But Privately Owned Utility On Property - Contact Private Utility Owner For Locate
conflict but privately owned utility on property - Contact private utility owner for locate
003YesExisting
Markings Adequate
markings adequate
004YesNo
Markings Requested
markings requested



010YesLocate
Area Marked
area marked
011YesLocate
Area Marked But Abandoned Facilities May Be In The Area
area marked but abandoned facilities may be in the area
012YesLocate
Area Marked Up To Private Owned Utility - Contact Private Utility Owner For Locate
area marked up to private owned utility - Contact private utility owner for locate
013YesLocate
Area Marked Up To Private Property
area marked up to private property
014NoPartially
Marked
marked - More
Time is Needed
time is needed
015YesProvided facility location information to excavator (4216.3(a)(1)(A)(ii))



020YesBad
Address
address/
Incorrect Street/Location Info
incorrect street/location info - Resend
Ticket Requested
ticket requested
021YesNo
Access To Locate Area
access to locate area - Resend
Ticket Requested
ticket requested
022YesNo
Delineation
delineation - Resend
Ticket Requested
ticket requested
023YesDelineated
Area Does Not Match Location Request - Resend Ticket Requested
area does not match location request - Resend ticket requested



030YesContact
Facility Owner For Further Info
facility owner for further info
031YesRequires
Stand By At Time Of Excavation - Contact Facility Owner
stand by at time of excavation - Contact facility owner
032YesVisible
Or Exposed Facility - Contact Facility Owner If Crossing
or exposed facility - Contact facility owner if crossing
033NoHigh
Priority Line
priority line in
Area
area - On
Site Meeting Required
site meeting required
034NoField
Meet Required - Contact Facility Owner to Schedule
meet required - Contact facility owner to schedule
035NoTraffic control required to mark facilities



040YesExcavator
Completed Work Prior To Due Date
completed work prior to due date
041YesExcavator
No Show For Meet
no show for meet
042YesExcavator
Canceled Request
canceled request



050NoNegotiated marking schedule
051NoMutually agreed to a later start date and time (4216.3(a)(1)(A))
052NoUnable to locate using standard locating techniques
053NoScheduled meet with excavator at requested date and time



080YesExtraordinary
Circumstances Exist
circumstances exist - No
Locate Due To Weather/Emergency Conditions
locate due to weather/emergency/safety conditions



999N/A
Reserved for
Member did not respond by required time (system use only)